Go to main contentGo to the menu

Low volume cell kits

Each voltammetry cell is designed for specific application (specific working electrode, solution volume, oxygen free conditions, etc.).  tała zaprojektowana do określonej aplikacji (specyficzna elektroda pracująca, objętość roztworu, warunki beztlenowe itp.). For example, for voltammetry investigations using standard working electrode with an outer diameter (OD) of 6 mm the fixed configuration of SVC-3 kit is recommended. For application requiring other working electrode shape, SVC-2 is more suitable. If only a small amount of the electroactive compound is available, SVC-2 in microvolume mode is recommended.

 

Cell geometry

 

The geometry of the cell should be optimized to reduce the ohmic drop. Working and reference electrodes have to be close to each other. The surface area of the counter electrode should be larger than the surface area of the working electrode.

 

The following cell kit models are available:

 

SVC-2 - modular kit

Catalog number: A-012668

 

Kit content:

  • Glass vial 20 ml, 7 pcs. (A-001056)
  • Platinum counter electrode, length: 57 mm (A-002222)
  • PTFE cap with mounting holes for electrodes and 10/6 mm WE adapter (A-012670)
  • ETFE purge tube, 10 cm (A-010537)

 

Optional accessories:

  • Sample vial holder (A-001209)

 

Working and reference electrodes are not included in the kit.

 

SVC-3 - kit for 6 mm OD working electrodes

Catalog number: A-012669

 

Kit content:

  • Glass vial 20 ml, 7 pcs. (A-001056)
  • Platinum counter electrode, length: 50 mm (A-002233)
  • PTFE cap with mounting holes for electrodes (A-012671)
  • ETFE purge tube, 10 cm (A-010537)

 

Optional accessories:

  • Sample vial holder (A-001209)

 

Working and reference electrodes are not included in the kit.

 

VC-4 - Kit for a volume of 1 to 3 ml

Catalog number: A-011224

 

Kit content:

  • Glass vial 5 ml, 7 pcs. (A-011504)
  • Platinum counter electrode, length: 57 mm (A-002222)
  • PTFE cap with mounting holes for electrodes (A-011226)
  • ETFE purge tube, 10 cm (A-010537)
  • Cell holder (A-011227)

 

Working and reference electrodes are not included in the kit.

 

Bulk electrolysis cell

Catalog number: A-001197

 

Kit content:

  • Glass vial100 ml, 1 pc (A-012632)
  • Porous carbon electrode (A-010530)
  • Platinum counter electrode (A-002234)
  • PTFE cap with mounting holes for electrodes (A-012551)
  • ETFE purge tube, 10 cm (A-010537)
  • Stirrer bar

 

Reference electrode is not included in the kit.

 

PHONE: +48 22 622 20 14

E-MAIL: office@lambdasystem.pl

LAMBDA SYSTEM

ul. Minska 25A lok. U12

03-808 Warsaw

enlighten by innovation